CB200 Replacement Copper Brazed Plate Heat Exchanger Condenser Evaporator for Heat Pump System Zl200

YOJO Heat Exchanger Advantage:High EfficiencyThe embossed pattern of the YOJO\'s special heat transfer plates promotes high turbulence at low fluid velocities. The high turbulence results in very high heat transfer coefficients.Compact SizeYOJO\'s brazed heat exchanger can be anywhere from 50% to 80% smaller than other types of

Featured Products

YOJO Heat Exchanger Advantage:

High Efficiency

The embossed pattern of the YOJO's special heat transfer plates promotes high turbulence at low fluid velocities. The high turbulence results in very high heat transfer coefficients.

Compact Size

YOJO's brazed heat exchanger can be anywhere from 50% to 80% smaller than other types of heat exchangers. It requires less floor space due to the high thermal efficiency of the stainless steel. The plates are brazed together at high temperatures, allowing the heat exchanger to be compact, leak tight, and rugged.

Close Approach Temperatures

Close-approach temperatures of 1-2°F (0.5-1.0°C) are possible because of true counter flow and high heat transfer efficiency of the plates. This is an important factor in regeneration and heat recovery processes.

High Temperature and Pressure Ratings

YOJO's Brazed Plate Heat Exchanger maximum working pressures from 300 psi to 650 psi, and temperature ratings of 350°F.
 

Brazed Plate Heat Exchanger
CB200 Replacement Copper Brazed Plate Heat Exchanger Condenser Evaporator for Heat Pump System Zl200CB200 Replacement Copper Brazed Plate Heat Exchanger Condenser Evaporator for Heat Pump System Zl200

Model 

A

 (mm)

B

(mm)

C

(mm)

D

(mm)

thickness

(mm)

weight

(mm)

Stagnant fluid 

volume (L)

Design pressure

(Mpa)

Max fluid

(L)

ZL14

76

42

172

206

9+2.3N

0.6+0.056N

0.010(N-2)

1/3/4.5

8m3/h

ZL18

95

50

165

210

9+3.1N

0.3+0.06N

0.010(N-2)

1

8m3/h

ZL20B

78

42

282

318

9+2.3N

0.9+0.088N

0.018(N-2)

3/4.5

8m3/h

ZL26

111

50

250

310

10+2.36N

1.3+0.12N

0.025(N-2)

3/4.5

18m3/h

ZL30

124

70

250

304

13+2.4N

2.2+0.146N

0.032(N-2)

3/4.5

18m3/h

ZL52A

111

50

466

525

10+2.35N

1.9+0.215N

0.047(N-2)

3/4.5

18m3/h

ZL52B

111

50

466

525

10+2.35N

1.9+0.213N

0.047(N-2)

3/4.5

18m3/h

ZL62B

119

63

470

526

10+2.35N

2.4+0.223N

0.051(N-2)

3/4.5

18m3/h

ZL95A

191

92

519

616

11+2.76N

6+0.415N

0.125(N-2)

3/4.5

42m3/h

ZL95B

191

92

519

616

11+2.76N

6+0.413N

0.125(N-2)

3/4.5

42m3/h

ZL120A

246

174

456

528

13+2.36N

7+0.472N

0.98(N-2)

3/4.5

42m3/h

ZL120B

246

174

456

528

13+2.36N

7+0.472N

0.98 (N-2)

3/4.5

42m3/h

ZL200A

321

188

603

738

9+1.58N

13+0.74N

0.22(N-2)

1.5/2.1/3

100m3/h

ZL200B

321

188

603

738

13+2.7N

13+0.73N

0.22(N-2)

1.5/2.1/3

100m3/h

High efficiency heat exchanger

Our ZL20, ZL62 series, ZL130, ZL250 are specifically developed for R410A refrigerant, which is ideal alternative of R22. R410A efficient heat exchanger is not only resistant to high pressure, but also with less refrigerant to achieve the same cooling effect. ZL20 and ZL62 are unilateral flow. ZL130 and ZL250 are diagonal flow. They can work from the power range of 1KW to 250KW.

CB200 Replacement Copper Brazed Plate Heat Exchanger Condenser Evaporator for Heat Pump System Zl200

Model

A

(mm)

B

(mm)

C

(mm)

D

(mm)

Thickness

(mm)

Weight

(mm)

Stagnant 

fluid

 volume (L)

Design

 pressure

(Mpa)

Max fluid

(L)

ZL20A

86

40

269

315

9+1.58N

1+0.084N

0.018(N-2)

3/4.5

8m3/h

ZL62A

119

63

470

526

10+2.35N

2.4+0.225N

0.051(N-2)

3/4.5

18m3/h

Model

A

(mm)

B

(mm)

C

(mm)

D

(mm)

E

(mm)

F

(mm)

Thickness

(mm)

Weight

(mm)

Stagnant 

fluid

 volume (L)

Design 

pressure

(Mpa)

Max fluid

(L)

ZL130

247

161

495

414

369

172

10+2.15N

4+0.424N

0.080(N-2)

3/4.5

42m3/h

ZL250

322

205.2

739

631.7

568

224.4

13+2.7N

16+0.711N

0.22(N-2)

3/4.5

100m3/h

 

Aircross
Aircross is a cross flow plate heat exchanger vacuume with pure copper or nickel based material. The top and bottom plates including side A connections are brazed to the plate package. This model can be asymmentrical for 1) applications with a smaller flow rate at high pressure on the one side ( Side A), and a larger flow rate at with lower pressure on the other ( Side B): different sizes for the connections In and Out, different channel lengths, different channel areas and volumes; 2) applications with a constant and defined gas flow on one side and medium with higher density on the other side. Normally YOJO-AirCross is used with a liquid on side A and gas on side B.
CB200 Replacement Copper Brazed Plate Heat Exchanger Condenser Evaporator for Heat Pump System Zl200

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours